CP 40KVA/40KW RACK UPS

Code: 8217900   
    CP 40KVA/40KW Rack UPS Specifications: - Phase: Three Phase - Form Factor: Rackmount, Tower - UPS Topology: Online Double Conversion - Energy Saving Technology: Online ECO Mode Efficiency > 98.9% - Normal Mode Efficiency: 95.8% - Battery Mode Efficiency: 95.5% - Active PFC Compatibility: Yes - Parallel Expansion (Max. Units): 4 - Dual Power Inputs: Yes - Generator Compatibility: Yes - Nominal Input Voltage: L-N: 220, 230, 240 Vac; L-L: 380, 400, 415 Vac - Input Voltage Range: L-N: 132 ~ 276 Vac; L-L: 228 ~ 478 Vac - Input Frequency Range: 40 ~ 70 Hz - Rated Input Current: 64.5 A - Input Power Factor: 0.99 - Overload Protection (Bypass): 125% Load continuous, 150% Load for 10 min, 1000% Load for 5 ms - Input Connector Type: Hardwire Terminal Block - Capacity: 40000 VA/Watts - On Battery Waveform: Pure Sine Wave - Output Voltage Setting: Configurable - Output Frequency Setting: Configurable - Rated Output Voltage: L-N: 220, 230, 240 Vac; L-L: 380, 400, 415 Vac - Output Voltage Tolerance: Balance Load: 1% - Output Frequency: 50 ± 0.2 Hz, 60 ± 0.166 Hz - Power Factor: 1 - ECO Mode Voltage Tolerance: ± 5% - Overload Protection: Internal Current Limiting, Fuse - Overload Protection (Line Mode): 102~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load for 200 ms - Overload Protection (Battery Mode): 102~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load for 200 ms - Crest Factor: 3:1 - Harmonic Distortion (Linear Load): THD ? 1% - Harmonic Distortion (Non-linear Load): THD ? 3% - Internal Bypass: Automatic Bypass - Synchronization Window (Nominal): 4 Hz - Outlet Type: Hardwire Terminal Block x 1 - Typical Transfer Time: 0 ms - Maximum Charging Current: 12 A - Typical Charging Current: 3.6 A - Compatible Battery Types: VRLA - Recharge Power Setting: Configurable - Charger Voltage Tolerance: ± 1% - Start On Battery: Yes - Smart Battery Management (SBM): Yes - Compatible Extended Battery Module (EBM): BME480V55ART5U - External Battery Quantity: 12V x 40 pcs - EMI/RFI Filtration: Yes - LCD Panel: Yes - LCD Types: Color LCD, LCD Touch Panel - LCD Orientation: Rotatable LCD - Manual - LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log - LCD Setting & Control: Mode Setting, Input & Output, Battery Setting, Communication, Event & Log, Security Setting, Language - LED Indicators: Yes - Shortcut Button: Alarm On/Off - Serial Port: RS232 x 1, RS485 x 1, Dry Contact x1 - Dry Contact (with Relay): Yes - Emergency Power Off (EPO) Port: Yes - Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery - Power Management Software: PowerPanel Business (Recommended) - SNMP/HTTP Remote Monitoring: Yes, with optional RMCARD205 - Compatible with Racks (3 Phase): Yes - Enclosure Construction: Metal - Color: Black - Ingress Protection: IP20 - Rackmount Rail: Yes - Dimensions: 433 x 219 x 730 mm - Weight: 42.8 kg - Installed Rack Height: 5 U - Operating Temperature: 0 ~ 40°C - Operating Relative Humidity (Non-condensing): 0 ~ 95% - Operating Elevation: 0-3,000 meters - Storage Temperature: -40 ~ 70°C - Storage Relative Humidity (Non-condensing): 0 ~ 95% - Audible Noise at 1.0M from Surface of Unit: 66 dBA (100% load), 56 dBA (50% load) Features: - Three-phase Design - High Output Power Factor - Color LCD Panel - Dual Inputs - Pure Sine Wave Output - Battery Cold Start - SNMP/HTTP Remote Management Capability (Optional) - Extended Battery Module (EBM) - Online (Double Conversion) UPS Topology - Rack Modular Design - LCD Touch Panel - Generator Compatible - UPS Parallel Expansion - Smart Battery Management (SBM) - PowerPanel Management Software

$9,048.60

EACH
Please note: Prices are shown including GST (where applicable) and are in AUD$

Our Brand Partners

Jaycar minelab leading edge office