CP 40KVA/40KW RACK UPS
Code: 8217900
- CP 40KVA/40KW Rack UPS
Specifications:
- Phase: Three Phase
- Form Factor: Rackmount, Tower
- UPS Topology: Online Double Conversion
- Energy Saving Technology: Online ECO Mode Efficiency > 98.9%
- Normal Mode Efficiency: 95.8%
- Battery Mode Efficiency: 95.5%
- Active PFC Compatibility: Yes
- Parallel Expansion (Max. Units): 4
- Dual Power Inputs: Yes
- Generator Compatibility: Yes
- Nominal Input Voltage: L-N: 220, 230, 240 Vac; L-L: 380, 400, 415 Vac
- Input Voltage Range: L-N: 132 ~ 276 Vac; L-L: 228 ~ 478 Vac
- Input Frequency Range: 40 ~ 70 Hz
- Rated Input Current: 64.5 A
- Input Power Factor: 0.99
- Overload Protection (Bypass): 125% Load continuous, 150% Load for 10 min, 1000% Load for 5 ms
- Input Connector Type: Hardwire Terminal Block
- Capacity: 40000 VA/Watts
- On Battery Waveform: Pure Sine Wave
- Output Voltage Setting: Configurable
- Output Frequency Setting: Configurable
- Rated Output Voltage: L-N: 220, 230, 240 Vac; L-L: 380, 400, 415 Vac
- Output Voltage Tolerance: Balance Load: 1%
- Output Frequency: 50 ± 0.2 Hz, 60 ± 0.166 Hz
- Power Factor: 1
- ECO Mode Voltage Tolerance: ± 5%
- Overload Protection: Internal Current Limiting, Fuse
- Overload Protection (Line Mode): 102~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load for 200 ms
- Overload Protection (Battery Mode): 102~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load for 200 ms
- Crest Factor: 3:1
- Harmonic Distortion (Linear Load): THD ? 1%
- Harmonic Distortion (Non-linear Load): THD ? 3%
- Internal Bypass: Automatic Bypass
- Synchronization Window (Nominal): 4 Hz
- Outlet Type: Hardwire Terminal Block x 1
- Typical Transfer Time: 0 ms
- Maximum Charging Current: 12 A
- Typical Charging Current: 3.6 A
- Compatible Battery Types: VRLA
- Recharge Power Setting: Configurable
- Charger Voltage Tolerance: ± 1%
- Start On Battery: Yes
- Smart Battery Management (SBM): Yes
- Compatible Extended Battery Module (EBM): BME480V55ART5U
- External Battery Quantity: 12V x 40 pcs
- EMI/RFI Filtration: Yes
- LCD Panel: Yes
- LCD Types: Color LCD, LCD Touch Panel
- LCD Orientation: Rotatable LCD - Manual
- LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
- LCD Setting & Control: Mode Setting, Input & Output, Battery Setting, Communication, Event & Log, Security Setting, Language
- LED Indicators: Yes
- Shortcut Button: Alarm On/Off
- Serial Port: RS232 x 1, RS485 x 1, Dry Contact x1
- Dry Contact (with Relay): Yes
- Emergency Power Off (EPO) Port: Yes
- Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
- Power Management Software: PowerPanel Business (Recommended)
- SNMP/HTTP Remote Monitoring: Yes, with optional RMCARD205
- Compatible with Racks (3 Phase): Yes
- Enclosure Construction: Metal
- Color: Black
- Ingress Protection: IP20
- Rackmount Rail: Yes
- Dimensions: 433 x 219 x 730 mm
- Weight: 42.8 kg
- Installed Rack Height: 5 U
- Operating Temperature: 0 ~ 40°C
- Operating Relative Humidity (Non-condensing): 0 ~ 95%
- Operating Elevation: 0-3,000 meters
- Storage Temperature: -40 ~ 70°C
- Storage Relative Humidity (Non-condensing): 0 ~ 95%
- Audible Noise at 1.0M from Surface of Unit: 66 dBA (100% load), 56 dBA (50% load)
Features:
- Three-phase Design
- High Output Power Factor
- Color LCD Panel
- Dual Inputs
- Pure Sine Wave Output
- Battery Cold Start
- SNMP/HTTP Remote Management Capability (Optional)
- Extended Battery Module (EBM)
- Online (Double Conversion) UPS Topology
- Rack Modular Design
- LCD Touch Panel
- Generator Compatible
- UPS Parallel Expansion
- Smart Battery Management (SBM)
- PowerPanel Management Software
Please note: Prices are shown including GST (where applicable) and are in AUD$