CP OL2000VA RACK TOWER UPS

Code: 8217898   
  • The CyberPower OL2000ERTXL2U offers dependable power backup for IT equipment, servers, workstations, NAS/storage devices, telecom, networking, security/emergency, and surveillance systems.

    Specifications:
    - Phase: Single Phase
    - Form Factor: Rackmount, Tower
    - UPS Topology: Online Double Conversion
    - Energy Saving Technology: Online ECO Mode Efficiency > 96%
    - Active PFC Compatibility: Yes
    - Generator Compatibility: Yes
    - Input Voltage Range (Vac): 190 - 300
    - Adjustable Voltage Range (Vac): 0-60% Load for 120 - 139 Vac
  • 0-70% Load for 140 - 159 Vac
  • 0-80% Load for 160 - 179 Vac
  • 0-90% Load for 180 - 189 Vac
  • 0-100% Load for 190 - 300 Vac
    - Input Frequency (Hz): 50 ± 10
  • 60 ± 10
    - Input Frequency Detection: Auto-sensing
    - Rated Input Current (A): 10
    - Input Power Factor: 0.99
    - Input Connector Type: IEC C14
    - Detachable Power Cord Plug Type: IEC C14 x 1
    - Power Cord Length (m): 3
    - Output Capacity (Watts): 1800
    - On Battery Waveform: Pure Sine Wave
    - On Battery Voltage(s) (Vac): 200 ± 2%
  • 208 ± 2%
  • 220 ± 2%
  • 230 ± 2%
  • 240 ± 2%
    - Output Voltage Setting: Configurable
    - On Battery Frequency (Hz): 50 ± 0.5%
  • 60 ± 0.5%
    - Output Frequency Setting: Configurable
    - Power Factor: 0.9
    - ECO Mode Voltage Tolerance: ± 10%
  • ± 15%
    - Overload Protection: Internal Current Limiting, Circuit Breaker
    - Overload Protection (Line Mode): 105-125% Load for 1 min, 125-150% Load for 10 sec
    - Overload Protection (Battery Mode): 105-130% Load for 10 sec, 130-150% Load for 2 sec
    - Overload Protection (Bypass Mode): Circuit Breaker
    - Crest Factor: 3:1
    - Harmonic Distortion (Linear Load): THD ? 3%
    - Harmonic Distortion (Non-linear Load): THD ? 5%
    - Internal Bypass: Automatic Bypass, Manual Bypass
    - Outlet(s) - Total: 9
    - Outlet Type: IEC C13 x 8
  • IEC C19 x 1
    - Outlet(s) - Battery & Surge Protected: 9
    - Outlet(s) - Critical Load (CL): 5
    - Outlet(s) - Non-Critical Load (NCL): 4
    - Typical Transfer Time (ms): 0
    - Runtime at Half Load (min): 20
    - Runtime at Full Load (min): 6.5
    - Typical Recharge Time (Hours): 5
    - Start On Battery: Yes
    - Smart Battery Management (SBM): Yes
    - Hot-swappable: Yes
    - Battery Type: Sealed Lead-acid
    - Battery Cartridge: RBP0076
    - RBP Quantity (pcs): 1
    - Battery Quantity (Each RBP) (pcs): 6
    - Battery Voltage (Each RBP) (V): 72
    - Compatible Extended Battery Module (EBM): BPE72V60ART2US
    - Max. EBM Quantity (pcs): 10
    - Surge Suppression (Joules): 1335
    - EMI/RFI Filtration: Yes
    - Phone/Network Protection RJ11/RJ45 (Combo): 1-in, 1-out
    - LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
    - LCD Setting & Control: Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting, Language
    - LED Indicators: Power On, Line Mode, Battery Mode, Bypass Mode, Battery Capacity, Low Battery, Overload, UPS Fault, Wiring Fault, Replace Battery
    - HID Compliant USB Port(s): 1
    - Dry Contact (with Relay): Yes
    - Emergency Power Off (EPO) Port: Yes
    - Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
    - Management Cable (pcs): Power Cord x1, USB Cable x1, Serial Cable x1, Phone Line x1
    - Power Management Software: PowerPanel Business (Recommended)
    - SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205
    - Enclosure Construction: Metal
    - Rackmount Rail: Yes
    - Rackmount Ears: Yes
    - Dimensions: 433 x 88 x 600mm
    - Weight: 31kg
    - Certifications: CE, BSMI, C-Tick

    Features:
    - Online (Double Conversion) UPS Topology
    - Generator Compatible
    - Critical/Non-critical Load Outlets
    - Smart Battery Management (SBM)
    - Extended Battery Module (EBM)
    - EMI and RFI Filtration
    - LCD Status Display
    - Emergency Power Off (EPO) Port
    - SNMP/HTTP Remote Management Capability (Optional)
    - ECO Mode
    - Overload Protection
    - Zero Transfer Time
    - Hot-swappable Batteries
    - Surge and Spike Protection
    - Phone/Fax/Modem/DSL/Network Protection
    - Detachable LCD Panel
    - PowerPanel Management Software
    - Rack/Tower Convertible Configurations

$3,073.32

EACH
Please note: Prices are shown including GST (where applicable) and are in AUD$