CP OLS RACK/TOWER 2000VA/1800W

Code: 8217909   
    CyberPower Systems Online S (A) 2000VA/1800W Rack UPS provides reliable power protection with a 12V/9AHx4 battery setup and 8 IEC C13 outlets. It features USB and Serial Ports, with an optional SNMP Slot (RMCARD205). The product includes a 2-year advanced replacement warranty and a rail kit. Specifications: - Phase: Single Phase - Form Factor: Rackmount, Tower - UPS Topology: Online Double Conversion - Energy Saving Technology: Online ECO Mode Efficiency > 95% - Active PFC Compatibility: Yes - Generator Compatibility: Yes - Nominal Input Voltage: 230 Vac ±10% - Input Voltage Range: 190 - 300 Vac - Adjustable Voltage Range: 0-30% Load for 80 - 300 Vac, 0-50% Load for 120 - 300 Vac, 0-75% Load for 160 - 300 Vac, 0-90% Load for 190 - 300 Vac, 0-100% Load for 200 - 300 Vac - Input Frequency: 50/60 Hz ±10 - Input Frequency Detection: Auto-sensing - Rated Input Current: 9 A - Input Power Factor: 0.99 - Input Connector Type: IEC C14 - Power Cord Length: 1.5 m - Output Capacity: 1800 Watts - On Battery Waveform: Pure Sine Wave - On Battery Voltage(s): 208, 220, 230, 240 Vac ±1% - Output Voltage Setting: Configurable - On Battery Frequency: 50/60 Hz ±0.5% - Output Frequency Setting: Configurable - Power Factor: 0.9 - ECO Mode Voltage Tolerance: ±15% - Overload Protection: Internal Current Limiting, Circuit Breaker, Fuse - Overload Protection (Line Mode): 110-120% Load for 1 min, >120% Load Immediately - Overload Protection (Battery Mode): 110-120% Load for 10 sec, >120% Load Immediately - Overload Protection (Bypass Mode): >130% Load Immediately - Crest Factor: 3:1 - Harmonic Distortion (Linear Load): THD ?3% - Harmonic Distortion (Non-linear Load): THD ?5% - Internal Bypass: Automatic Bypass, Manual Bypass - Total Outlets: 8 - Outlet Type: IEC C13 x 8 - Battery & Surge Protected Outlets: 8 - Critical Load Outlets: 4 - Non-Critical Load Outlets: 4 - Typical Transfer Time: 0 ms - Runtime at Half Load: 11.9 min - Runtime at Full Load: 4 min - Typical Recharge Time: 4 hours - Maximum Charging Current: 1.5 A - Start On Battery: Yes - Smart Battery Management (SBM): Yes - User-replaceable: Yes - Qualified Personnel Only - Battery Type: Sealed Lead-acid - Battery Cartridge: RBP0157 - RBP Quantity: 1 - Battery Quantity (Each RBP): 4 - Battery Voltage (Each RBP): 48 V - Compatible Extended Battery Module (EBM): BPSE48V40ART2U - Extended Battery Module Auto-detection: Yes - Max. EBM Quantity: 3 - Surge Suppression: 363 Joules - EMI/RFI Filtration: Yes - Phone/Network Protection RJ11/RJ45 (Combo): 1-in, 1-out - LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log - LCD Setting & Control: Mode Setting, Alarm Setting, Input & Output, Battery Setting - HID Compliant USB Port(s): 1 - Dry Contact (with Relay): Yes - Emergency Power Off (EPO) Port: Yes - Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery - Management Cable: Power Cord x2, USB Cable x1 - Power Management Software: PowerPanel Business (Recommended) - SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205 - Enclosure Construction: Metal - Rackmount Rail: Yes - Rackmount Ears: Yes - Dimensions: 438 x 88 x 430 mm - Weight: 19.2 kg - Certifications: CE, RCM Features: - Online (Double Conversion) UPS Topology - Generator Compatible - Zero Transfer Time - Extended Battery Module Auto-detection - Critical/Non-critical Load Outlets - Phone/Fax/Modem/DSL/Network Protection - Variable Speed Fans - PowerPanel Management Software - Rack/Tower Convertible Configurations - ECO Mode - Overload Protection - Smart Battery Management (SBM) - Surge and Spike Protection - EMI and RFI Filtration - Color LCD Panel - Emergency Power Off (EPO) Port - SNMP/HTTP Remote Management Capability (Optional)

$1,465.27

EACH
Please note: Prices are shown including GST (where applicable) and are in AUD$

Our Brand Partners

Jaycar minelab leading edge office